Prier C-434Y06 6-Inch Self-Draining Wall Hydrant, 1/2-Inch Press-Fit
Brand: Prier | SKU: C-434Y06
Product Overview
The Prier C-434Y06 combines a 6-inch insertion and 1/2-inch press-fit inlet with C-434’s self-draining design. It provides outdoor hose access and drains after shutoff even with a closed-end hose attached. Match the reach to the wall and supply position so the shutoff remains inside a heated area.
Key Features
- 6-inch nominal insertion with a 1/2-inch press-fit inlet.
- Self-draining design works after shutoff with a hose attached.
- Anti-siphon vacuum breaker and double check valves.
- Solid brass body with satin nickel plating and soft-grip handle.
Common Uses
Outdoor watering and maintenance hose connections where the supply uses compatible press-fit plumbing and the installed valve can drain properly.
Technical Specifications
- Model: C-434Y06
- Series: C-434
- Nominal insertion: 6 inches
- Inlet: 1/2-inch press-fit (Y style)
- Operation: Soft-grip handle
- Body: Solid brass, satin nickel plated
- Protection: Anti-siphon vacuum breaker and double check
- Maximum pressure: 125 PSI
- Maximum temperature: 140 F
Dimensions
Nominal insertion: 6 inches
Inlet: 1/2-inch press-fit
Insertion length is not complete assembly overall length.
Compatibility & Installation Notes
Confirm the 6-inch insertion against the wall depth and supply layout before ordering. Install horizontally with the flange flush to a vertical wall and the spout downward, following PRIER’s drainage instructions. Keep the shutoff in a heated space, flush the supply before connection and use compatible press fittings and tooling. The self-draining function does not protect an incorrectly installed or obstructed hydrant.
Frequently Asked Questions
What is the inlet connection?
C-434Y06 has a 1/2-inch press-fit inlet. Use compatible fittings and press tooling.
Will it drain with a closed-end hose attached?
Yes. PRIER’s C-434 design drains after shutoff even with a closed-end hose attached, provided it is installed correctly.
What does the listed length mean?
6 inches is the nominal insertion length. Check the wall thickness and supply position to place the shutoff inside a heated area.
Is water draining behind the handle normal?
Brief drainage behind the packing nut after shutoff is part of the C-434 design. Persistent leakage should be inspected.
Why Buy from Big Frog Supply?
Choose C-434Y06 when the installation needs a 6-inch reach and 1/2-inch press-fit supply connection. Pairing those fit details with C-434’s hose-attached drainage helps you compare it with a standard wall hydrant before ordering.






Reviews
There are no reviews yet.